DRAN EXPERT
ENERGY/POWER LOGGER & PQ DETECTOR
DranXperT measures all of the power parameters that you expect, such as W, VA, VAR, PF, Demand and Energy. Being a bidirectional power meter, direction of power flow is also measured for use in DER/alternative energy applications. Being a Dranetz, DranXperT’s measurements are second to none and also include PQ monitoring capabilities. PQ problems, such as sags/dips, swells, interruptions can be detected with IEC 61000-4-30 1/2 cycle resolution and harmonics are computed using the techniques of IEEE 519-2014/IEC 61000-4-7.
Introducing DranXperT – a new portable, low cost, power logger and PQ detector from Dranetz.
DranXperT is two products in one:
Accurate, 3 phase, bi-directional power/energy logger
PQ detector with 1/2 cycle resolution to identify and record common PQ issues such as sags/dips, swells, and interruptions, as well as changes in current
DranXperT measures all of the power parameters that you expect, such as W, VA, VAR, PF, Demand and Energy. Being a bidirectional power meter, direction of power flow is also measured for use in DER/alternative energy applications. Being a Dranetz, DranXperT’s measurements are second to none and also include PQ monitoring capabilities. PQ problems, such as sags/dips, swells, interruptions can be detected with IEC 61000-4-30 1/2 cycle resolution and harmonics are computed using the techniques of IEEE 519-2014/IEC 61000-4-7.
DranXperT includes free, unlicensed Dran-View XP software, a web browser user interface, and strong remote communications for use in virtually any portable, or temporary power monitoring application. Connect your computer directly to DranXperT using the supplied Ethernet cable, or to any local/private/corporate network, and even the Internet for remote communications. All that you need is a web browser on any PC, tablet or Smartphone to configure the meter for recording and for real time data review. Data is easily transferred for analysis to your PC via a USB drive or by downloading using your web browser.
No other product at this price point can achieve this high level of capability – a complete bi-directional energy/power meter AND the PQ monitoring capabilities that you expect from a Dranetz
GENERAL
- Sampling Frequency: 32ksps (recorded and real-time meters), 128 samples per cycle (periodic waveform snapshots)
- Journal Rate: User selectable (1 sec min interval)
- Snapshot Rate: User selectable (60 sec min interval)
- Demand Interval Storage Rate: User selectable (1 min to 1440 min)
- Sag/dip, swell trigger resolution: 1 cycle (uses IEC 61000-4-30 Class S methods)
- Panel indicators: RGB LEDs for monitoring on/off, energy flow, PQ event indication, battery charging/status, wiring status
- Storage Capacity: 8GB
MEASUREMENT INPUTS
Voltage (3)
- Range: 90 to 600Vrms CATIII
- Accuracy: 90 Vrms to 600Vrms = ±0.1%, <90 Vrms = 0.5%
- Connections: 4 safety banana voltage inputs – 3 phase voltage and 1 neutral/reference
Current (4)
- Input: 0.333 Vrms full scale
- Accuracy: ±0.1% + probe
- Connections: BNC
Frequency
- Range: 50Hz = 45Hz to 55Hz, 60Hz = 55Hz to 65Hz
- Accuracy: 50/60Hz: ±0.001Hz
ENERGY PARAMETERS (probe dependent)
- (True/Active) Energy (P): 0.1%
- Reactive Energy (Q): 0.1%
- Apparent Energy (S): 0.1%
- Fundamental Active Energy(P): 0.2%
- Fundamental Reactive Energy(Q): 0.2%
- Fundamental Apparent Energy (S): 0.2%
- Demand: 0.2%
POWER PARAMETERS (probe dependent)
- (True/Active) Power (P): 0.2%
- Reactive Power (Q): 0.2%
- Apparent Power (S: 0.2%
- Fundamental Active Power(P): 0.2%
- Fundamental Reactive Power (Q): 0.2%
- Fundamental Apparent Power (S): 0.2%
- Power Factor (PF): ±0.001%
POWER QUALITY
- Sag/dip, swell trigger threshold resolution: 1 cycle
- Periodic waveform snapshots: 1 cycle
- Vthd: ±5% for V ≥ 10% Vnom
- Ithd: ±5% for I ≥ 10% Inom + probe error
TYPES OF CONNECTIONS
- Single phase
- Split phase
- 3 wire wye
- 3 wire delta – 2 probe
- 3 wire delta – 3 probe
INSTRUMENT POWER
Line Power Supply
- Range: 90 to 264 VAC, 47 to 63Hz
- Consumption: 15W max
- Line cords/plugs: Localized – country dependent. US, EU, UK, Australia available
Internal Battery
- Rechargeable lithium Ion battery pack (UL recognized)
- Run time: 7 hours (typical)
- Charge time: 15 hours (typical)
COMMUNICATION INTERFACES
- Ethernet: 10
- USB: 2.0
- Protocols: Modbus, Bacnet
ENCLOSURE & MECHANICAL
Mechanical
- Weight: 1.4 lb. (0.64Kg)
- Dimensions: 3.5” Width x 2.2” Height x 7.4” Length (6.4 cm x 8.9 cm x 18.8cm)
- Material: Aluminum
- Ingress protection rating: IP50 (vertical position)
Environmental
- Storage Temperature: 5 to 131 °F (-15 to +55 °C)
- Operating Temperature: 32 to 113 °F (0 to +45 °C)
- Humidity: 5% to 95% non-condensing
- Altitude: 6560 ft (2000m) maximum (per EN61010-1)
SAFETY
UL
- EN 61010-1
- Mains supply: Installation Category II, Pollution Degree 2
- Measurement Inputs: Installation Category III, Pollution Degree 2
CE
- EN 61326
- CISPR 11
- EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
Key Features
Power/energy logger & PQ disturbance/event detector
3 voltage channels
4 current channels
Measures: V, I, W (P), VA (S), VAR (Q), PF, Demand, Energy & much more
PQ disturbance detector
Harmonic measurements & recording
Web browser interface
Free, unlicensed Dran-View XP
7 hr battery runtime
Automatic wiring verification
Ethernet, USB communications
Modbus, Bacnet
UL and CE Compliant
3 Year Warranty
Other Products
TOR-1
Transformer Oil Express Test Kit TOR detects moisture in oil quickly and precisely – even in miniscule quantities.
Express test kits have been developed specifically to detect the amount of moisture in dielectric insulation oils, which is necessary for normal operation and timely maintenance of electric equipment. The high precision and excellent long-term stability make this testing device an ideal solution for continuous monitoring of moisture in transformer oils.
The test kit is compact, reliable, simple to operate and multifunctional; it is the best choice for moisture measurement. The device also measures such parameters as water activity (aw), temperature (t), and calculates absolute water content in ppm. The device combines everything necessary for simple and comfortable operation: two digital displays to indicate sample temperature moisture content in ppm, a detachable sample container and two buttons: power and measurement.
TOR-80
The TOR-80 unit is designed to determine the electric breakdown voltage of transformer oil and other liquid dielectrics in accordance with IEC 60156, ASTM D877, ASTM
D1816, GOST 6581. It is a fully automatic device that allows testing to be performed according to the procedures specifed in these standards, as well as user procedures specifed in the
appropriate section of the setup menu.
GUIDE PS400