HIGHLY PORTABLE FAULT LOCATION SYSTEM FOR MV NETWORKS

the EZ-Thump series are the most portable fault location systems on the market. It utilises the “Easy Go” test system, which is easy to operate, interprets the results and requires minimal training to find faults.
On-board is a TDR with a 7.6 km range and arc reflection at 4 or 12 kV respectively for pre-locating. For pinpointing, the EZ-Thump offers a surge energy of 500 J, d.c. testing for breakdown detection and insulation resistance measurement. The units are operated from line or the internal battery. They can fit in the boot of a car, making them ideal for a flexible quick response fault finding strategy.
All EZ-Thump models are compact, battery and AC line operated, portable cable fault location systems. They are designed for quick, effective, accurate and safe fault locating operations to greatly reduce system customer outage minutes.
Due to their rugged yet portable enclosure, they are ideally suited for all typical fault locating operations on MV cable as well as on LV cables.
The 12 kV model can be used as part of a “satellite” fault locating concept for remote areas that may have less frequent faults, when ease of operation, light weight and economics are important, or for hard to access inner-city locations.
The 3 kV and 4 kV units offer a convenient solution for industrial fault locating applications up to 3 or 4 kV, street light fault locating or fault locating in LV power circuits in the utility industry, featuring point-to-point cables.
The units require no adjustments and are operated via a rotary control knob.
• Compact, light and rugged field instruments
• Battery and AC line operation
• Automatic end-of-cable and fault locating
• 4-kV or 12-kV output versions available
• Transflective colour display
• ARM® Prelocation
• Fault Pinpointing (Thumping)
• DC Testing for breakdown detection
• ARM Prelocation
• Sheath testing and sheath fault locating
• Insulation Resistance Measurement

Key Features
TDR method to prelocate very low resistance cable faults, either phase to phase or phase to neutral, or by pair comparison
Arc Reflection Method (ARM®) prelocation of high resistance flashover faults.
Single stage 500 Joule surge generator for pinpointing of high resistive faults up to 12kV
DC testing for breakdown detection
Insulation resistance measurement.
Sheath testing and sheath fault locating
Other Products
GUIDE PS400
The Guide PS Series high-performance thermal camera is designed to make the inspection, maintenance and troubleshooting work easier, faster and more accurate.

V3 Transmission Line Monitoring System
Module Outputs:
- Conductor sag and vertical clearance from ground for each individual phase
- Horizontal conductor displacement/blowout for each individual phase
- Conductor tension
- Conductor temperature
- Circuit current
- MW, MVAR, MVA and Power Factor
- Icing alerts
- Galloping alerts
- Local ambient weather conditions
- Anomalous motion alerts
- User configurable alert notifications

Battery Operated Crimpers (LEC-U27)
Height : 323 mm
Weight : 6.1 kgs (w/o battery)
■ Specifications :
Drive unit : 18V DC motor
Charger (GS/CE) :
Input voltage : 110V single phase AC
Input voltage : 230V single phase AC
Input frequency : 50~60Hz
Input current : 21.75 VA
Reservoir capacity : 120 cc