TriRaptor
Three Phase Primary Injection

The TriRaptor combines three single-phase Raptor Master units and a special three-phase user interface to provide seamless, stabilized 120° wye or delta injection of high current in substation commissioning and primary equipment testing jobs.
CHARACTERISTIC
• Portable 35-kg elements with wheels and handle
• Dynamic output stabilization
• Multi-functionality
• Expandability
• Convenient and efficient pass-through technique
• Pre-configured tests
• Test & results storage, download and reporting
• Internet connection
APPLICATIONS
• Substation commissioning
• Three-phase primary testing
The TriRaptor can be powered from a 230VAC single phase supply as long as it measures up to the injection power required by each particular job.
The three injection cables are attached to both ends of each phase in the tested section (substation bus) or measurement / protection device and made into a common (neutral) at one of the ends. Then the operator pre-selects the desired injection value for each phase on the touch screen and presses the ON button. In timing applications, the 1-millisecond chronometer will start counting and the test will stop when an external signal is detected or a predefined duration has elapsed.
All results including time and external measurements can be saved in the console’s permanent memory for future download and analysis on a Windows PC.

Key Features
Automatic output regulation with digital technology
Multifunctionality for most primary injection testing
Loop-through high current technique
Flexible modularity and adaptability
Modern, robust and upgradeable technology
Smart handheld controller with touch screen
Other Products
GUIDE PS400
The Guide PS Series high-performance thermal camera is designed to make the inspection, maintenance and troubleshooting work easier, faster and more accurate.

V3 Transmission Line Monitoring System
Module Outputs:
- Conductor sag and vertical clearance from ground for each individual phase
- Horizontal conductor displacement/blowout for each individual phase
- Conductor tension
- Conductor temperature
- Circuit current
- MW, MVAR, MVA and Power Factor
- Icing alerts
- Galloping alerts
- Local ambient weather conditions
- Anomalous motion alerts
- User configurable alert notifications

Battery Operated Crimpers (LEC-U27)
Height : 323 mm
Weight : 6.1 kgs (w/o battery)
■ Specifications :
Drive unit : 18V DC motor
Charger (GS/CE) :
Input voltage : 110V single phase AC
Input voltage : 230V single phase AC
Input frequency : 50~60Hz
Input current : 21.75 VA
Reservoir capacity : 120 cc