Megger has been a leader in electrical test and measurement globally for 130 years. From power generation to the power outlets in your home, Megger products cover almost every application.
Megger.

PRODUCTS
VLF SIN 62
VLF sine wave test system for medium voltage cables with integrated Tan Delta
- Performs cable withstand testing, cable diagnosis, and sheath fault pinpointing
- Smallest and lightest unit on the market in its class
- Unique user-experience, thanks to a large, colour touch screen
- Automatic result interpretation as per latest IEEE 400.2 standard
- High safety, thanks to its analogue residual voltage indicator
TDM 45
High power test and diagnosis combination for MV cables (Tan Delta, VLF and PD)
- Cable testing, cable diagnosis, and sheath testing in one device
- Enables standard compliant high power VLF testing at 0.1 Hz (5 µF at 40 kV RMS)
- Internal tan delta measurement with automatic result interpretation
- Partial discharge diagnosis using VLF sine wave, damped AC or 50/60 Hz slope technology voltages
VLF SIN 45
The VLF Sine Wave 45 kV is a compact VLF sine wave test system
- Test capacity of up to 1 0μF – that’s up to 40 km or 25.8 miles of cable at reduced frequency and voltage
- Internal tan delta option with automatic results interpretation
- One minute burn after fault detection
- Automatic frequency adjustment based on cable length
- Adjustable DC pulse rates of 1:3 and 1:4
- IEEE compliant withstand testing for new installations up to 25 kV
- IEEE 400.2 compliant maintenance testing up to 35 kV
- IEC 60229 compliant sheath testing up to 20 kV DC
MIT515, MIT525, MIT1025, and MIT1525
MIT is DC insulation resistance testers with a full suite of test modes
- Measures up to 30 TΩ
- PI, DAR, DD, SV and ramp test
- Improved productivity – operate from line power/mains if battery dead
- Li ion battery – extended capacity, rapid charge
- Advanced memory with time/date stamp
- CATIV 600 V safety rating
Torkel 900 – Series
Gain a comprehensive insight into battery capacity with discharge testing
- Discharge testing for full insight into battery capacity
- Enhanced safety features including spark free connection and emergency safety fuse
- Ability to test the battery without disconnecting it from the system
- High discharge capacity shortens the test time
- A complete stand-alone discharge test system
TELEFLEX® VX-PT V2
The Teleflex® VX-PT V2 is a portable, stand-alone, three phase time domain reflectometer (TDR)
- Bright and large display
- Easiest operation via self guiding and explaining menus
- ARM Multishot technology
- Automatic storage of all results
- Supports all existing prelocation technologies
- Automatic detection and display of cable end and fault position
High-voltage test system HPG 50-H – 110-H
The AC voltage test sets HPG 50, 80 and 110-H are suitable for 50 / 60 Hz AC testing of low capacity test objects
- HPG 50-H, AC testing up to 35 kVRMS / DC-testing up to 50 kV
- HPG 70 / 80-H, AC testing up to 50 / 58 kVRMS / DC-testing up to 70 / 80 kV
- HPG 110-H, AC testing up to 78 kVRMS / DC-testing up to 110 kV
VLF CR series
Portable, high-performance, and energy-efficient Cosine rectangular VLF cable test systems
• VLF, DC and sheath fault testing in one device
• Portable thanks to two-part construction
• High test capacitance
• Integrated discharge system
• Reporting
EZ-THUMP™ 12 kV, Model V3
Portable cable fault location for medium voltage (MV) networks
The EZ-Thump 12 kV makes accurate fault finding on underground MV distribution power cables quick and easy
Compact, light and rugged field instruments
• Battery and AC line operation
• Automatic end-of-cable and fault locating
• 4-kV or 12-kV output versions available
• Transflective colour display
• ARM® Prelocation
• Fault Pinpointing (Thumping)
PRIME ON
Prime ON is Centrally controlled and automated cable fault location and cable testing system in one vehicle
- Insulation resistance testing
- Time domain reflectometry (Radar)
- HV DC testing (DC hipot)
- Fault conditioning (Burning)
- TDR-based and transient methods
- Magnetic-acoustic pinpointing via surging/thumping in multiple voltage ranges
- Sheath testing and sheath fault pinpointing
Teleflex SX-1
The Teleflex SX-1 is a portable two-channel time domain reflectometer (TDR) designed to provide quick, effective, accurate, and safe pre-location of faults in cable installations.
- Standalone operation or operation in conjunction with surge wave generators (thumpers)
- Single jog dial operation with piechart interface and No-User-Intervention Auto mode ARM®
- Multishot technology with 15 fault traces per arc reflection shot
- ProRange distance-dependent de-attenuation for significantly improved images of far-away reflections
- Supports all existing HV prelocation methods
- Auto-ranging cable end recognition, Auto-find cursor to fault position
- Rugged, robust, outdoor field-ready case
Cable Identifier
The CI/LCI cable identifier will safely identify a dead (or de-energized) primary cable within a group of energized or de-energized cables
- Identifies a de-energized primary cable safely
- Identifies live secondary cables up to 240 VAC
- Avoids false positives
Ferrolux
The Ferrolux Rx audio frequency receiver with IFS tracing sensor can locate lines and cable faults with a high level of precision as it combines several functions in one device.
- Plan view of the target line location
- Excellent results, even when cables are bunched
- Location of joints
- Modular sensor design (plug and play)
- Multifunctional system combines the most
- effective pinpointing methods in one device
Digiphone Plus 2
Shockwave receiver for acoustic and electromagnetic fault location
- Acoustic-magnetic cable fault location
- Highest acoustic noise immunity
- Automatic filtering of interference signals
- Automatic adjustment of all parameters, no adjustment necessary
- Optional: Bluetooth® headphones
- Optional: step voltage location (NT Set)
- Optional: cable tracing (NTRX Set)
Centrix Evolution
Flagship system for state-of-the-art cable fault location, cable testing and cable diagnostics
- State-of-the-art fault location system with options for the functional integration of Very Low Frequency (VLF) testing, Partial Discharge (PD) diagnostics and tan delta measurement
- Centrally controlled: One single control unit for all operating modes and all system functions
- Fully automated: Automatic switching in all operating modes via motorised switches
- Great user convenience: Operation entirely by multi-touch with smartphone-inspired touchscreen gestures; pull-through sequence guiding users through fault location; integrated data management with MeggerBook 3 database and reporting software
- Equipped with technologies for identifying, pre-locating, pinpointing, and converting cable faults; suitable for main insulation faults and sheath faults; handles MV cables, LV cables, and even HV cables to a certain extent
- Comes with Teleflex RDR, cable radar/TDR technology
- Comes with HV pre-location methods ARM, ARM conditioning, ICE, and decay
- Available HV setups: 80 kV DC, either single phase or three phase
- Available with automated resonance burn-down unit for fault conversion, ARM Live Burning for pre-location, and surge energies of up to 4000 J for pinpointing (thumping)
- Available with VLF sine wave units, internal tan delta measurement, and sine wave-PD diagnostics
- Available with high standard-compliant VLF test capacity and technologies for near line frequency PD diagnostics on 36 kV cables, including PD-monitored withstand testing: VLF CR, DAC and Slope up to 60 kV RMS
Categories
Usage
PRODUCTS
VLF SIN 62
VLF sine wave test system for medium voltage cables with integrated Tan Delta
- Performs cable withstand testing, cable diagnosis, and sheath fault pinpointing
- Smallest and lightest unit on the market in its class
- Unique user-experience, thanks to a large, colour touch screen
- Automatic result interpretation as per latest IEEE 400.2 standard
- High safety, thanks to its analogue residual voltage indicator
TDM 45
High power test and diagnosis combination for MV cables (Tan Delta, VLF and PD)
- Cable testing, cable diagnosis, and sheath testing in one device
- Enables standard compliant high power VLF testing at 0.1 Hz (5 µF at 40 kV RMS)
- Internal tan delta measurement with automatic result interpretation
- Partial discharge diagnosis using VLF sine wave, damped AC or 50/60 Hz slope technology voltages
VLF SIN 45
The VLF Sine Wave 45 kV is a compact VLF sine wave test system
- Test capacity of up to 1 0μF – that’s up to 40 km or 25.8 miles of cable at reduced frequency and voltage
- Internal tan delta option with automatic results interpretation
- One minute burn after fault detection
- Automatic frequency adjustment based on cable length
- Adjustable DC pulse rates of 1:3 and 1:4
- IEEE compliant withstand testing for new installations up to 25 kV
- IEEE 400.2 compliant maintenance testing up to 35 kV
- IEC 60229 compliant sheath testing up to 20 kV DC
MIT515, MIT525, MIT1025, and MIT1525
MIT is DC insulation resistance testers with a full suite of test modes
- Measures up to 30 TΩ
- PI, DAR, DD, SV and ramp test
- Improved productivity – operate from line power/mains if battery dead
- Li ion battery – extended capacity, rapid charge
- Advanced memory with time/date stamp
- CATIV 600 V safety rating
Torkel 900 – Series
Gain a comprehensive insight into battery capacity with discharge testing
- Discharge testing for full insight into battery capacity
- Enhanced safety features including spark free connection and emergency safety fuse
- Ability to test the battery without disconnecting it from the system
- High discharge capacity shortens the test time
- A complete stand-alone discharge test system
TELEFLEX® VX-PT V2
The Teleflex® VX-PT V2 is a portable, stand-alone, three phase time domain reflectometer (TDR)
- Bright and large display
- Easiest operation via self guiding and explaining menus
- ARM Multishot technology
- Automatic storage of all results
- Supports all existing prelocation technologies
- Automatic detection and display of cable end and fault position
High-voltage test system HPG 50-H – 110-H
The AC voltage test sets HPG 50, 80 and 110-H are suitable for 50 / 60 Hz AC testing of low capacity test objects
- HPG 50-H, AC testing up to 35 kVRMS / DC-testing up to 50 kV
- HPG 70 / 80-H, AC testing up to 50 / 58 kVRMS / DC-testing up to 70 / 80 kV
- HPG 110-H, AC testing up to 78 kVRMS / DC-testing up to 110 kV
VLF CR series
Portable, high-performance, and energy-efficient Cosine rectangular VLF cable test systems
• VLF, DC and sheath fault testing in one device
• Portable thanks to two-part construction
• High test capacitance
• Integrated discharge system
• Reporting
EZ-THUMP™ 12 kV, Model V3
Portable cable fault location for medium voltage (MV) networks
The EZ-Thump 12 kV makes accurate fault finding on underground MV distribution power cables quick and easy
Compact, light and rugged field instruments
• Battery and AC line operation
• Automatic end-of-cable and fault locating
• 4-kV or 12-kV output versions available
• Transflective colour display
• ARM® Prelocation
• Fault Pinpointing (Thumping)
PRIME ON
Prime ON is Centrally controlled and automated cable fault location and cable testing system in one vehicle
- Insulation resistance testing
- Time domain reflectometry (Radar)
- HV DC testing (DC hipot)
- Fault conditioning (Burning)
- TDR-based and transient methods
- Magnetic-acoustic pinpointing via surging/thumping in multiple voltage ranges
- Sheath testing and sheath fault pinpointing
Teleflex SX-1
The Teleflex SX-1 is a portable two-channel time domain reflectometer (TDR) designed to provide quick, effective, accurate, and safe pre-location of faults in cable installations.
- Standalone operation or operation in conjunction with surge wave generators (thumpers)
- Single jog dial operation with piechart interface and No-User-Intervention Auto mode ARM®
- Multishot technology with 15 fault traces per arc reflection shot
- ProRange distance-dependent de-attenuation for significantly improved images of far-away reflections
- Supports all existing HV prelocation methods
- Auto-ranging cable end recognition, Auto-find cursor to fault position
- Rugged, robust, outdoor field-ready case
Cable Identifier
The CI/LCI cable identifier will safely identify a dead (or de-energized) primary cable within a group of energized or de-energized cables
- Identifies a de-energized primary cable safely
- Identifies live secondary cables up to 240 VAC
- Avoids false positives
Ferrolux
The Ferrolux Rx audio frequency receiver with IFS tracing sensor can locate lines and cable faults with a high level of precision as it combines several functions in one device.
- Plan view of the target line location
- Excellent results, even when cables are bunched
- Location of joints
- Modular sensor design (plug and play)
- Multifunctional system combines the most
- effective pinpointing methods in one device
Digiphone Plus 2
Shockwave receiver for acoustic and electromagnetic fault location
- Acoustic-magnetic cable fault location
- Highest acoustic noise immunity
- Automatic filtering of interference signals
- Automatic adjustment of all parameters, no adjustment necessary
- Optional: Bluetooth® headphones
- Optional: step voltage location (NT Set)
- Optional: cable tracing (NTRX Set)
Centrix Evolution
Flagship system for state-of-the-art cable fault location, cable testing and cable diagnostics
- State-of-the-art fault location system with options for the functional integration of Very Low Frequency (VLF) testing, Partial Discharge (PD) diagnostics and tan delta measurement
- Centrally controlled: One single control unit for all operating modes and all system functions
- Fully automated: Automatic switching in all operating modes via motorised switches
- Great user convenience: Operation entirely by multi-touch with smartphone-inspired touchscreen gestures; pull-through sequence guiding users through fault location; integrated data management with MeggerBook 3 database and reporting software
- Equipped with technologies for identifying, pre-locating, pinpointing, and converting cable faults; suitable for main insulation faults and sheath faults; handles MV cables, LV cables, and even HV cables to a certain extent
- Comes with Teleflex RDR, cable radar/TDR technology
- Comes with HV pre-location methods ARM, ARM conditioning, ICE, and decay
- Available HV setups: 80 kV DC, either single phase or three phase
- Available with automated resonance burn-down unit for fault conversion, ARM Live Burning for pre-location, and surge energies of up to 4000 J for pinpointing (thumping)
- Available with VLF sine wave units, internal tan delta measurement, and sine wave-PD diagnostics
- Available with high standard-compliant VLF test capacity and technologies for near line frequency PD diagnostics on 36 kV cables, including PD-monitored withstand testing: VLF CR, DAC and Slope up to 60 kV RMS